1¡¢ÒDZíÓ¦´¹Ö±°²×°ÓÚ-20¡æ-55¡æ£¬Ïà¶Ôʪ¶È²»´óÓÚ85%£¬ÎÞÄ͸¯Ê´ÐÔÆøÌ壬ÎÞÇ¿ÁÒÕñ¶¯µÄ»·¾³ÖС£»·¾³Î¶ȣ¨±»²â½éÖÊζȣ©Æ«Àë20¡æ¡À5¡æÊ±£¬Ð뿼ÂÇζÈÓ°ÏìËùÔì³ÉµÄÎó²î¡£ 2¡¢ÄÍÕñ±í°²×°Ê±Ó¦¾¡Á¿±ÜÃâ±í¿Ç¡¢ÕÖȦÊÜÁ¦£¬·ÀÖ¹ÆÆ»µ±íµÄÃܷ⣬Ôì³ÉÒDZíµÄ¹à³äÒºÉøÂ©¡£ 3¡¢ÔÚ²âÁ¿ÒºÌåѹÁ¦Ê±£¬ÒDZíÓ¦Óë²âѹµã±£³ÖÍ¬Ò»Ë®Æ½Ãæ£¬·ñÔòÓ¦¿¼ÂÇÒòҺλ²îËù²úÉúµÄ²âÁ¿Îó²î¡£ 4¡¢²âÁ¿¸ßÑ¹ÆøÌå»ò¾çÁÒ²¨¶¯µÄ½éÖÊѹÁ¦Ê±£¬Ó¦¸½¼Ó»º³å×°Öᣠ5¡¢ÒDZíÔÚ²âÁ¿¾ùÔȱ仯µÄѹÁ¦Ê±£¬¹¤×÷ѹÁ¦Ó¦²»´óÓÚÆä²âÁ¿ÉÏÏÞµÄ3/4£¬²âÁ¿²¨¶¯Ñ¹Á¦Ê±£¬¹¤×÷ѹÁ¦Ó¦²»´óÓÚÆä²âÁ¿ÉÏÏÞµÄ2/3¡£ 6¡¢ÒDZíÔÚʹÓÃʱӦ½ÓÈë24VDCµçÔ´¡£ 7¡¢ÒDZí½ÓÈë¿ØÖÆÏµÍ³Ê±£¬Æä½Óµã×°ÖÃÒ»°ã×÷ΪÖ÷ÁîµçÆøÊ¹Óã¬Ê¹ÓÃʱӦעÒâ½ÓÈëÒDZíµÄ¸ºÔع¦ÂÊ£¬µçѹ¼°µçÁ÷¾ù²»µÃ³¬¹ýÆä¶î¶¨Öµ¡£ 8¡¢ÒDZíÉ趨ÕëµÄÉ趨£¬¿ÉÓÃÒ»×Ö²ÛÂÝË¿µ¶½«µ÷½Ú×°ÖõIJ¦Æ¬Ñ¹ÏºóÐýת£¬½«É趨ָÕ벦ÖÁËùÐè¿ØÖÆÑ¹Á¦µÄ±ê¶È´¦£¬ÄÍÕñ±íÔÚÉ趨Íê³ÉºóÓ¦½«µ÷½Ú×°ÖõÄÃÜ·âñÐýÉÏ£¬·ÀÖ¹ÒDZíÄڵĹà³äҺ©³ö¡£ 9¡¢ÄÍÕñ±íµÄÍâ¿ÇÊÇÃÜ·âµÄ£¬»·¾³Î¶ȱ仯»áÔì³É±í¿ÇÄÚ²¿Ñ¹Á¦²úÉú±ä»¯½ø¶øÓ°ÏìÒDZíµÄ¾«¶È£¬Òò´ËÔÚʹÓÃʱӦ½«°²×°ÔÚÒDZíÉϲ¿µÄÏð½ºÈûµÄÍ»³ö²¿·Ö¼ôÈ¥£¬Ê¹ÒDZíÄÚ²¿Óë´óÆø½Óͨ¡£ 10¡¢¸ù¾ÝËùÓÃÒDZíµÄÀàÐͰ´Í¼½«ÏàÓ¦µÄ½ÓÏߺ¸½ÓÔÚº½¿Õ²åÍ·µÄ½ÓÏß¶Ë×ÓÉÏ¡£
1, meters should be installed on the vertical -20 ¡æ -55 ¡æ, relative humidity of not more than 85 percent, Wu Nai corrosive gases, without a strong vibration environment. Ambient temperature (measured medium temperature) from 20 ¡æ ¡À 5 ¡æ, to take into account the temperature caused by the impact of the error. 2, vibration-resistant forms should be installed to avoid Case, cover laps force to prevent the destruction of the seal table, resulting in leakage of fluid-filled instrument of irrigation. 3, in the measurement of liquid pressure, the instrument should be maintained at the same horizontal plane pressure points, or should be considered due to poor level generated by measurement error. 4, measuring high-pressure gas or sharp fluctuations in the medium pressure, should additional buffer. 5, measuring instruments in the uniform changes in pressure, the pressure should not limit its measurement of 3 / 4, measuring fluctuations in pressure, the pressure should not limit its measurement of the 2 / 3. 6, in the use of instruments should be access 24 VDC power. 7, gauges access control system, its general as the main contact devices to electrical use, the use of instruments should pay attention to access the load power, voltage and current shall not exceed their ratings. 8, the set-setting instrument, the word slot screwdriver can be used to adjust the device for film pressure after rotation, will be required to set guidelines for the control of pressure on the scale, resistant to vibration table should be set after the completion of The seal-conditioning apparatus rotation, the instrument to prevent the leakage of liquid-filled irrigation. 9, vibration-resistant form of the shell was sealed, environmental temperature changes will cause Case internal pressure changes in turn affect the accuracy of instrumentation, the use of instruments should be installed in the upper part of the outstanding rubber Cypriot cut so that the internal instrument Connected with the atmosphere. 10, according to the type of instrument used by the appropriate wiring plans will be welded in the aviation plug on the Connection. |